Verace Helios
Detailed-balance simulations of two photovoltaic designs: a planar micro-tracking multi-junction concentrator and a non-reciprocal flat panel.
- Unconcentrated sunlight: 1 sun: light enters but cannot leave
- Non-reciprocal trapping: Assumed 99% trapping efficiency in simulation
- Garnet metasurface: Proposed to suppress back-emission
- 1.7 eV perovskite absorber: Design layer; simulated as a 5-junction stack
Overview
Verace Helios is the lab's line of work on solar panel design from first principles. It asks how far a panel can exceed conventional silicon once real device losses are included, and it answers that question through two designs. The first is the Planar Micro-Tracking Multi-Junction Concentrator (PMMJC), a flat concentrating photovoltaic panel. The second is the Topological Non-Reciprocal Light Magnet (TNRLM), a flat panel designed to run under unconcentrated sunlight and to break time-reversal symmetry so that the cell does not radiate light back to the sky. Both are evaluated with a shared detailed-balance simulation, which bounds cell efficiency by balancing absorbed and emitted photons.
The PMMJC places a static micro-lens array over a sheet of 5-junction III-V micro-cells (InGaP/GaAs/InGaAsP/InGaAs/Ge). The cells cover 0.2% of the aperture, and the sheet moves on silicone flexures by up to ±1.2 mm to follow the sun. The TNRLM puts a gyrotropic bismuth iron garnet metasurface and a traveling-wave modulated ITO electrode grid over a 1.7 eV perovskite absorber. The design proposes that light enters but cannot leave, so that absorption and emission decouple: . The simulation code solves the diode equation with series resistance, temperature derating and an optional photon-trapping term, and compares each design with a silicon reference.
The simulation reports explain why earlier ideal-diode models overstated concentrator gains. Ohmic loss grows as . At 2000x, the cell draws 14.6 A/cm², which produces a 0.15 V internal drop. With , a 75 C junction and 83% lens efficiency, PMMJC efficiency is 40.24% at 100x, peaks at 40.89% at 300x, and falls to 37.03% at 2000x. The silicon reference reaches 23.53%. The annual average falls to 32.71% because diffuse light is lost. For the TNRLM at 1 sun, with an assumed 99% trapping efficiency, the evaluation records report 51.83% (518.3 W/m²) for a 5-junction stack rather than the design's single 1.7 eV perovskite absorber, net of a 5 W/m² RF overhead.
Status: the two designs exist as written specifications, and both are evaluated only in simulation. No device has been fabricated or measured. The PMMJC and TNRLM figures are outputs of the lab's detailed-balance model, not hardware results. The TNRLM design documents claim 70 to 78%, and its cost ledger cites 74.2%, while the lab's simulation gives 51.83%. Each design names a dissociating measurement that would falsify it, and a falsification sweep exists in code, but no measurement is recorded. The same records also hold separate theoretical physics documents on emergent spacetime, which are not part of the solar designs.
Status
Experiments. Simulation code and simulation reports with recorded efficiency figures exist for both designs; no hardware was built or measured.
Simulator
A thin layer absorbs part of the light that crosses it. Keep the light inside for longer, with a mirror behind the layer or with a textured surface, and watch the share absorbed.
- the bar at the right: the share of the light absorbed
- Light absorbed
- 9.5%
- Light lost
- 90.5%
- Path inside, in thicknesses
- 1
- Limit for a textured surface
- 49.0 thicknesses
Keep the layer thin and change how the light is kept inside: the same material absorbs several times more.
This simulator is an illustration of the principle, with made-up numbers. It does not run the lab's code or show the lab's data, and nothing in it is a measurement.
Architecture
PMMJC micro-concentrator
A flat concentrating panel made of a static micro-lens array over a movable sheet of multi-junction micro-cells, designed for 300x concentration.
5-junction III-V micro-cell
An InGaP/GaAs/InGaAsP/InGaAs/Ge stack operated at 300x and 75 C, covering 0.2% of the aperture area.
Elastomeric flexure tracking stage
Silicone springs that suspend the micro-cell sheet. They allow ±1.2 mm of translation for tracking without sliding friction.
Passive copper-via cooling
A heat path through copper vias that rejects the focal-spot heat flux and holds the junctions at 75 C.
TNRLM non-reciprocal panel
An unconcentrated 1-sun panel designed to break time-reversal symmetry so that trapped photons are not re-emitted to the sky.
Bismuth iron garnet metasurface
A gyrotropic nanoparticle film with strong Faraday rotation that the design proposes to suppress back-emission in the TNRLM.
Traveling-wave ITO electrode grid
A dynamically modulated electrode grid, driven by RF, designed to break time-reversal symmetry. The simulation charges it 5 W/m² of overhead.
1.7 eV perovskite absorber
A roll-to-roll, slot-die-coated, direct-gap perovskite beneath the metasurface, designed to convert the trapped photons. The simulation does not model this single absorber: it models a 5-junction stack.
Implementation
Mechanisms as they are implemented in the source code, with the constants the code uses.
- Radiative dark saturation current
calculate_detailed_balance_with_rs()computes the radiative limit for each junction bandgap. Raising the cell temperature to 348 K raises this term exponentially.- Non-radiative loss through EQE_EL
- The radiative current is divided by the junction's electroluminescent external quantum efficiency, . This term models non-radiative recombination separately for each junction.
- Newton solve of implicit diode equation
- The terminal current solves by 15 Newton steps. The exponent is capped at 150 to avoid overflow.
- Maximum power point search
- For each junction and operating condition, the code sweeps the voltage and takes . The system efficiency follows from the summed output.
- PMMJC operating configuration
simulate_ssmqh_optimized.pyevaluates the concentrator at , a cell temperature of 348 K and an optical efficiency of 0.83. It compares the result with single-junction silicon in efficiency and cost per watt.- Non-reciprocal trapping EQE boost
simulate_tnrlm.pymodels the proposed photon trapping by dividing by . With , an assumed input value, this lowers 100-fold and raises by per junction.- RF driver overhead deduction
- A fixed 5 W/m² modulation-driver cost is subtracted from the TNRLM output before the net efficiency is reported.
- Falsification sweep
test_falsification.pydefinesrun_falsification_sweep(), which reruns the system simulation over varied conditions. No output of this sweep is recorded.
Results
From the lab's own experiments and records. They have not been independently replicated.
Ideal-diode models overstate concentrator gains
The lab's simulation report notes that earlier ideal-diode models predicted 51% at 500x and 64% at 2000x. Adding series resistance and thermal derating removed these gains.
PMMJC efficiency peaks at 300x
In the lab's simulation, efficiency is 40.24% at 100x, 40.89% at 300x, 40.78% at 500x, 39.78% at 1000x, 37.03% at 2000x and 35.62% at 2500x. The silicon reference reaches 23.53%.
Diffuse light loss lowers annual efficiency
Assuming 80% DNI capture, the simulated annual average efficiency at 300x is 32.71%.
Ohmic drop at high concentration
With , operation at 2000x draws 14.6 A/cm² and produces a 0.15 V internal drop, according to the simulation report.
TNRLM simulated at 51.83% under 1 sun
The evaluation records report 51.83% (518.3 W/m²) for a 5-junction stack with bandgaps of 2.1, 1.7, 1.4, 1.1 and 0.75 eV at an assumed 99% trapping efficiency, after a 5 W/m² RF overhead. This stack is not the single 1.7 eV perovskite absorber the design describes.
TNRLM design claims exceed its simulation
The TNRLM design documents claim 70 to 78% flat 1-sun efficiency, and the cost ledger cites 74.2%. The lab's own simulation gives 51.83%.
Concepts
- Detailed balance limit
- An efficiency bound in which a cell's emission is set by its absorption and temperature. The dark saturation current follows from this balance and determines the open-circuit voltage.
- Series resistance scaling
- Ohmic loss grows quadratically with current, . Because concentration multiplies current, this loss eventually collapses the fill factor.
- Optimal concentration at 300x
- In the lab's simulation, efficiency peaks at 300x. Beyond that point, ohmic losses outpace the voltage gain from concentration.
- Junction temperature derating
- At 75 C rather than 25 C, rises exponentially. The design documents put the resulting loss at 0.15 to 0.25 V per junction.
- DNI versus diffuse light
- Concentrators focus only direct normal irradiance (DNI). Diffuse light, 20 to 40% of the annual total, is lost, which lowers the annual average efficiency.
- Lorentz reciprocity
- For a reciprocal cell, absorption equals emission, so a 1-sun panel must radiate back over the full sky hemisphere. This clamps its efficiency.
- Breaking time-reversal symmetry
- The design proposes a non-reciprocal device that decouples absorption from emission. The design documents state that this raises the 1-sun limit from 68.2% toward the 86.8% Landsberg limit.
- Trapping efficiency
- is the fraction of emission the metasurface is proposed to suppress. It enters the model as , and the simulation sets it to 99% as an assumed input, not a measured value.
- Chern number edge states
- The TNRLM design states that broken time-reversal symmetry opens a topological bandgap with one-way edge states () that guide photons into the absorber.
- Dissociating measurement
- A single experiment that would falsify a design's central claim. For the PMMJC, it is a fill factor below 80% at 300x and 75 C. For the TNRLM, it is emitted power above 1% of the reciprocal blackbody at 300 K.
- Honesty ledger
- Each design document sorts its claims into proven, buildable and speculative categories and ends with a verdict. The PMMJC is judged buildable now; the TNRLM is judged buildable at a price.
About this page
Written from the lab's own documents and source code. Figures and results are the lab's measurements as it recorded them at the time, and have not been independently replicated.
Published under the PolyForm Noncommercial License 1.0.0: free for noncommercial use.