Verace Neocortex: research audits and reports
Per-module engineering audits, stability theorems and validation verdicts for a biologically constrained cortical-column language model.
- L1 top-down wire: Zero initialisation severed it; now normal initialisation
- L2/3 synaptic scaling: Theorem L23-Scaling specifies replacing hard clamps
- L4 weight-norm clamp: Fired on the first step at initial norm 10.25
- L5 sigmoid-derivative trap: Biases set to 0.0 to remove a 5.54x slowdown
Overview
This part of Verace Neocortex holds the lab's audit log, theorem notes and validation reports for the cortical-column language model, called NeuroCortex Transformer (NCT) in the lab's papers. It records how each module was checked against biology and engineering rules, which defects were found, and which runs failed. The central question is why the columns of the model homogenize during training, losing their differences, and which changes to initialisation, gating and homeostasis prevent that collapse.
The audits follow a fixed procedure. An engineer reads a module and all its wiring, and classifies any useless-looking code as not wired, not engineered or not researched. Fixes under ten lines that leave the biology untouched are applied directly. Deeper issues go to a research review. Every module is checked against 12 implementation rules: neonatal non-zero initialisation, no new bounds, no CPU synchronisation inside the forward pass, and others. Separate theorem notes then specify replacement mechanisms: multiplicative synaptic scaling, bus weight homeostasis and surprise-triggered precision rescue.
The 2026-04-09 engineer pass landed 23 commits. The status report counts about 40 dead-parameter sites fixed (18 frozen to buffers, 22 wired with learning rules) and 506/506 tests plus 12/12 smoke tests passing at every commit. One fix removed a sigmoid-derivative trap in L5 that had slowed learning by a factor of 5.54. Later records turn negative. Gate variance fell to 0.0007. The round-4 critical-period closure run failed at default scale, and column health scored 46/100. A round-5 gate audit then ruled that 89 gate sites must be redesigned or removed.
The records are audits, theorem specifications and run verdicts. The code changes they describe are recorded as committed and tested. The theorems for synaptic scaling, bus weight homeostasis and precision rescue are specified with update rules and constants, but several are marked deferred. Column homogenization was not solved: round 4 failed, the round-5 gate redesign is a ruling and not yet a result, and about 40 to 60 dead parameters were still unaudited at the time of the session report.
Status
Experiments. The audit log and session report record committed fixes with passing test suites, and validation reports record failed training runs, while several theorem-level redesigns remain specified but deferred.
Simulator
A made-up signal jumps a few times. A running prediction follows it, and a gate passes the prediction error upwards only when it is large for the precision it is given.
- signal (white) and prediction (colour), synthetic data
- prediction error: passed upwards (colour) or held (faint)
- Steps passed upwards
- 23%
- Gate stays open after a jump for
- 8.5 steps
- Mean size of the error
- 0.26
- Jumps in the signal
- 4
Raise the precision and small errors pass as well. Lower the learning rate and the prediction takes longer to catch up after a jump.
This simulator is an illustration of the principle, with made-up numbers. It does not run the lab's code or show the lab's data, and nothing in it is a measurement.
Architecture
Per-module engineer audit log
One findings record per module in checklist order, covering L1 through the cortical column integration, each marking a verdict, the fixes applied, the regression tests and the deferred research questions.
Twelve implementation rules
The rule set every module is audited against. It includes neonatal activity at initialisation, no new bounds, updates under no_grad and no .item() calls in the forward pass.
Three-way dead-code diagnosis
The required triage before touching any code that looks useless. The code is classified as not wired, not engineered or not researched, and each class calls for a different fix.
Dead-learnable parameter sweep
A sweep across modules for parameters that are declared learnable but receive no gradient or update. Each is either frozen to a buffer as a biological constant or wired to a learning rule.
Homeostasis theorem notes
Specifications that replace hard clamps with biological regulation. They include Theorem L23-Scaling, Theorem MC-W and Theorems R-1 and R-2.
Gate architecture audits
Round-5 catalogue and rulings on about 76 to 89 gate sites. The audits ban the transformer-era single-scalar gate and prescribe circuit-based redesigns.
Validation and restart reports
Verdicts on training rounds. They cover the failed round-4 critical-period closure, the round 22.1 intrinsic pacemaker and the restart decision with its watch metrics.
Assessment documents
The lab's scorecards of the architecture against general-intelligence pillars, in a full multimodal version and a text-only version.
Results
From the lab's own experiments and records. They have not been independently replicated.
L5 sigmoid-derivative trap fixed
The audit log records that the W_dend and W_apical biases were 3.0, causing a 5.54x learning attenuation. Setting them to 0.0 gave an empirically verified 5.24x and 5.28x speedup.
About 40 dead parameters fixed, many unaudited
The 2026-04-09 session report counts about 40 sites fixed (18 frozen to buffers, 22 wired with learning rules) across 23 commits, with 506/506 tests and 12/12 smoke tests passing at each commit. About 40 to 60 sites remained unaudited.
Initialisation and buffer defects in column modules
The zero-initialised L1 projection weight severed the top-down wire at construction; it and the L2/3 W_dist were changed to normal initialisation with std 0.01, and the audit log records that the L1 fix passed 6/6 regression tests and 12/12 smoke tests. The L4 weight-norm clamp at 10 fired on the first step because the initial norm was 10.25, which grew the Turrigiano scaling sweep from 5 to 9 sites. The sst_tonic buffer was overwritten every step, erasing a Broca asymmetry of 0.099 against 0.069, and was fixed as a property of sst_tonic_raw.
Prenatal convergence check trivially satisfied
The audits record a P0 bug: the prenatal stage measures gate evolution from a hardcoded baseline of -2.0 instead of the configured gate_init of 0.0, which makes convergence condition 4 trivially true.
Uniform random tokens collapsed precision to NaN
In the lab's TEST 13, uniform random tokens drove to its floor, which overflowed a batched matrix multiply and produced NaN.
Scalar gates drive column homogenization
The lab's records report gate_var falling to 0.0007, attributed to more than 21 single-scalar gate sites, which blocked further theorem implementation. The forward-path diagnosis found that 38 retained transformer-era scalar gate sites broadcast a shared signal that homogenizes the columns on every forward pass, which plasticity damping cannot fix.
Round-4 critical-period closure failed
The prenatal stage passed, but the nursery stage at d=512 reproduced the round-3 collapse, with col_diff 1.002, gate_var 0.0009 and column health 46/100.
Round-5 rulings leave no gate standing as a gate
The gate audit ruled 89 actionable sites as roughly 72 to redesign, 15 to remove, 8 to keep as readouts and 2 to keep as algebra, with none kept as a gate.
Prenatal precision gradient erodes
The asymmetry records show the precision gradient across columns 0 to 10 compressing linearly to 55% of its baseline span by step 2574.
Intrinsic pacemaker raised synchrony only in bench toys
The round 22.1 verdict reports bench toys reaching R of 0.748 and 0.619 against a pinned 0.124 in the model.
Concepts
- Column homogenization
- The failure mode the audits track: cortical columns that start different converge to near-identical weights and gates. In the lab's records, L2/3 association weights drift in lockstep across columns with a coefficient of variation of 0.005.
- Neonatal activity at init
- Rule 1 of the implementation rules. Every module must make a small, structured, non-zero contribution at construction, with gates at and small random weights, and zero initialisation is forbidden on learning-participating weights.
- Sigmoid-derivative trap
- A gate bias that pushes a sigmoid into saturation shrinks its derivative and stalls learning. The L5 dendritic bias of 3.0 gave 0.045 against 0.25 at bias 0, a 5.54x attenuation.
- Dead-learnable parameter
- A parameter registered as learnable that has no gradient path or update rule, for example one read only through .item(). The audits either freeze it to a buffer or wire a learning rule to it.
- Hill dose-response receptor curve
- Readouts such as D1 dopamine, working-memory confidence and basal ganglia drift use . The audits treat these as fixed protein-level constants to be frozen.
- Turrigiano synaptic scaling
- Multiplicative scaling of a neuron's weights toward a firing-rate setpoint. Theorem L23-Scaling uses it to replace weight-norm soft clamps, with target rate 0.15.
- BCM homeostasis
- A sliding threshold between strengthening and weakening of synapses that adapts to squared postsynaptic activity. It is used for the boundary and merge thresholds of the language circuits.
- Metaplasticity meta-meta rule
- Following Abraham and Bear, the plasticity rate itself adapts. A time constant drifts with a plasticity moving average, bounded between 50 and 5000 steps.
- Multicast neuromodulator buses
- Three buses carry noradrenaline (A), acetylcholine (B) and dopamine (C), and memory and column modules subscribe to them. Many subscriptions initialised at alpha_raw of -5.0 were deferred pending an architecture review.
- Neuromodulated plasticity gate
- Plasticity is scaled as . The records give about 0.14 in the neutral state.
- Protomap symmetry breaking
- A per-column bias with std 0.02 and per-column gate noise of 0.3 encode areal gradients, following the protomap idea of Rakic 1988, to keep columns distinct. L2/3 receives half the gate noise.
- Banned single-scalar gate
- The round-5 mandate forbids the transformer-era gate, a linear map to one unit followed by a sigmoid. Every gate site must be redesigned as a biological circuit, for example gamma-phase coherence for lateral gates.
- Surprise-triggered precision rescue
- Theorem R-2 computes a surprise ratio . It fires the R-1 rescaling when S exceeds 100 in a column or 20 on average.
- Homeostatic rescaling at shifts
- Theorem R-1 re-bootstraps precision, the BCM threshold and metaplasticity when the training phase or sequence length shifts. It replaces snapshot rollback.
- Rollback misattribution
- The lab's audit found that the papers cited to justify snapshot rollback, Frey and Morris 1997 and Botvinick 2001, do not describe weight restoration. It also found that rollback created its own failures: fluke best losses, stale optimizer state and curriculum feedback loops.
- Next-token prediction as Chinese room
- The lab's diagnosis that next-token loss can keep improving while the cortex homogenizes, with column 11, which serves as the language-model head, bearing the prediction burden.
- Critical-period closure
- A plasticity-damping mechanism after Hensch 2005 that locks rewritten cortical gates. The round-4 report found it necessary but insufficient to stop the collapse.
- Kuramoto order parameter
- A measure R of phase synchrony across oscillators. The round 22.1 pacemaker was intended to lift R from a pinned 0.124, and the records classify R trajectories into outcomes A to E.
- Three-timescale working memory
- A persistent attractor with 4 slots, an activity-silent synaptic trace after Tsodyks and Markram, and a phonological loop with 8 slots.
- Drift-diffusion sampler
- In the lab's technical reference, token selection during generation maps 17 brain signals to 6 drift-diffusion parameters. A separate audit of the sampler found 12 of its parameters dead-learnable, read only through
.item()with no gradient or update rule.
About this page
Written from the lab's own documents and source code. Figures and results are the lab's measurements as it recorded them at the time, and have not been independently replicated.
Published under the PolyForm Noncommercial License 1.0.0: free for noncommercial use.